Skip main navigation
Committee

Committee:

CTN 85 - Closure of frames in building and related products

Secretary:
ASEFAVE - ASOCIACIÓN ESPAÑOLA DE FABRICANTES DE FACHADAS LIGERAS Y VENTANAS
Field of Activity:
Standardization of: Terminology, symbols, classification, characteristics, test methods and marking of: - Doors, windows, blinds and shutters; - Building hardware and locks; - Curtain walling; - Glass in building. Excluding: - Indoor wooden doors ; - Safety glass. NOTE: Indoor doors means doors subjected to similar atmospheric conditions in both sides of the door.
Structure:

SC 4 Building hardware and locks

GT 1 Puertas peatonales automáticas

GT 5 Puertas industriales

GT 8 Fire

International Relations:

ISO/TC 160  Glass in building

ISO/TC 162  Doors, windows and curtain walling

CEN/SS H34  Child Safety

CEN/TC 33  Doors, windows, shutters, building hardware and curtain walling

CEN/TC 129  Glass in building

CEN/WS BRESAER  Innovative and adaptable envelopes in building refurbishment. Design, economic assessment, logistics and installation guidelines

* Some activities of this TC correspond to other AEN/CTN.

Standards developed by the committee: CTN 85: 494

UNE-EN 13330:2014

Status: VIGENTE2024-06-04

Shutters - Hard body impact and prevention of access - Test methods

UNE-EN 12428:2014

Status: VIGENTE2024-06-04

Industrial, commercial and garage doors - Thermal transmittance - Requirements for the calculation

UNE-EN 14351-2:2019

Status: VIGENTE2024-06-04

Windows and doors - Product standard, performance characteristics - Part 2: Internal pedestrian doorsets

UNE-EN 12153:2024

Status: VIGENTE2024-04-17

Curtain walling - Air permeability - Test method

UNE-EN 12152:2024

Status: VIGENTE2024-04-17

Curtain walling - Air permeability - Performance requirements and classification

UNE-EN 14024:2024

Status: VIGENTE2024-04-17

Metal profiles with thermal barrier - Mechanical performance - Requirements, proof and tests for assessment

UNE-EN 13126-6:2019

Status: VIGENTE2024-03-04

Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 6: Variable geometry stay hinges (with or without a friction stay)

UNE-EN 12519:2019

Status: VIGENTE2024-03-04

Windows and pedestrian doors - Terminology

UNE-EN 12758:2020+A1:2024

Status: VIGENTE2024-01-24

Glass in building - Glazing and airborne sound insulation - Product descriptions, determination of properties and extension rules

UNE-EN 13120:2010+A1:2014

Status: VIGENTE2024-01-01

Internal blinds - Performance requirements including safety

UNE-EN 13126-8:2018

Status: VIGENTE2024-01-01

Building hardware - Hardware for windows and door height windows - Part 8: Requirements and test methods for Tilt and Turn, Tilt-First and Turn-Only hardware

UNE-EN 950:2000

Status: VIGENTE2024-01-01

Door leaves - Determination of the resistance to hard body impact

UNE-EN 12216:2018

Status: VIGENTE2024-01-01

Shutters, external blinds, internal blinds - Terminology, glossary and definitions

UNE-EN 12604:2018+A1:2021

Status: VIGENTE2024-01-01

Industrial, commercial and garage doors and gates - Mechanical aspects - Requirements and test methods

UNE-EN 1191:2013

Status: VIGENTE2024-01-01

Windows and doors - Resistance to repeated opening and closing - Test method

UNE-EN 13126-3:2023

Status: VIGENTE2023-12-20

Building hardware - Hardware for windows and door-height windows - Requirements and test methods - Part 3: Handles, primarily for Tilt and Turn, Tilt-First and Turn-Only hardware

UNE-EN 17635:2023

Status: VIGENTE2023-12-20

Glass in building - Shatter properties - Requirements and assessment methods

UNE-EN 17352:2023

Status: VIGENTE2023-10-31

Power operated pedestrian entrance control equipment - Safety in use - Requirements and test methods

UNE-EN 17610:2023

Status: VIGENTE2023-10-31

Building hardware - Environmental product declarations - Product category rules complementary to EN 15804 for building hardware

UNE-EN 13050:2011

Status: VIGENTE2023-03-08

Curtain Walling - Watertightness - Laboratory test under dynamic condition of air pressure and water spray